Genlock is the technique of locking all video equipment to one reference signal, so their frames start at exactly the same time.
A sync generator produces the reference signal and distributes it to cameras, switchers, recorders and converters. In SDI systems the reference is black burst or tri-level sync. Each device sets its own clock by it.
When every source arrives aligned, the switcher cuts without delaying or repeating frames. That is why genlock is in every TV studio, every OB truck and every system with several cameras. Sources that do not accept reference go through frame synchronizers.
In IP infrastructure with SMPTE 2110, the reference becomes the PTP protocol, distributed over the network itself. The job is the same: one clock for the whole plant.
Related terms